Skip to main content
. 2020 Mar 14;10:20. doi: 10.1186/s13550-020-0616-4

Table 3.

Variability and reliability of test-retest parameters from 10 healthy volunteers after injection of [18F]LSN3316612

Parametera Source Testb Retestb TRV (%) aTRV (%) ICC
VT Brain and plasma 13.7 (19.2) 15.3 (19.6) 11.3 12.5 0.64
AUC150–180 Brain 102.2 (16.3) 103.6 (11.9) 1.8 9.0 0.68
AUC/CP150–180 Brain and plasma 654.1 (46.2) 661.1 (19.7) 6.5 31.9 0.18

Plasma parent

AUC0–∞

Plasma 105.9 (20.3) 96.0 (20.3) − 9.7 12.3 0.69

Brain

AUC0–∞

Brain 1428.2 (23.3) 1445.5 (20.6) 1.6 13.3 0.78

TRV test-retest variability, aTRV absolute test-retest variability, ICC intraclass correlation coefficient, VT total distribution volume, AUC area under the curve, TAC time-activity curve

aThe measured parameters were VT total distribution volume (mL·cm−3); AUC150–180 area under the curve of brain TAC of 150–180 min; AUC/CP150–180 normalized AUC150–180 to mean parent radioactivity concentration in arterial plasma; AUC0–∞ area under the curve estimated from 0 min to infinity

bData are presented as mean with coefficient of variation (%) in parentheses