Skip to main content
. 2020 Feb 6;9(2):439. doi: 10.3390/jcm9020439

Table 1.

Characteristics and endpoint definitions of included randomized trials.

Study Year Location N Study Design Primary Endpoint Mortality Reported Valve Type Randomization Follow-Up (Years)
NOTION 2015 Multicenter 280 RCT Death from any cause, stroke, or myocardial infarction Yes CoreValve (Medtronic) TAVR vs. SAVR 1
ELRT 2019 Multicenter 1403 RCT Death from any cause or disabling stroke Yes CoreValve, Evolut R, or Evolut PRO (Medtronic) TAVR vs. SAVR 1
PARTNER 3 2019 Multicenter 950 RCT death from any cause, stroke, or rehospitalization Yes Sapien 3 (Edwards) TAVR vs. SAVR 1

Abbreviations: RCT = randomized clinical trials; TAVR = transcatheter aortic valve replacement; SAVR = surgical aortic valve replacement.