Table 12:
MOS-SS Score, Mean ± SD | 10-kHz High-Frequency SCS |
Conventional SCS | Differencea |
---|---|---|---|
Somnolence | |||
Baseline | 51.79 ± 23.04 | 53.10 ± 28.87 | −1.31 |
Mean change, baseline to 12 months | −15.4 ± 21.65 | −10.0 ± 27.06 | — |
Sleep Disturbance | |||
Baseline | 29.66 ± 25.13 | 27.20 ± 25.24 | 2.46 |
Mean change, baseline to 12 months | −11.59 ± 24.92 | −10.12 ± 27.95 | — |
Sleep Quantity | |||
Baseline | 5.25 ± 1.17 | 5.03 ± 1.37 | 0.22 |
Mean change, baseline to 12 months | −0.48 ± 1.40 | −0.41 ± 1.63 | — |
Awake Short of Breath | |||
Baseline | 57.69 ± 31.15 | 57.93 ± 34.37 | −0.24 |
Mean change, baseline to 12 months | −19.23 ± 35.09 | −7.07 ± 43.16 | — |
Snoring | |||
Baseline | 43.08 ± 38.65 | 34.48 ± 36.12 | 8.6 |
Mean change, baseline to 12 months | −8.46 ± 31.07 | −5.71 ± 24.25 | — |
Sleep Adequacy | |||
Baseline | 27.42 ± 24.51 | 31.03 ± 26.23 | −3.61 |
Mean change, baseline to 12 months | −12.58 ± 34.16 | −6.83 ± 38.63 | — |
Abbreviations: MOS-SS, Medical Outcomes Study-Sleep Scale; SCS, spinal cord stimulation; SD, standard deviation.
Crude differences calculated for this health technology assessment.
Source: De Andres et al, 2017.29