Skip to main content
. 2020 Feb 5;12(2):341. doi: 10.3390/polym12020341

Figure 2.

Figure 2

(a) Temperature and (b) pressure evolutions recorded during injection molding experiments performed with 150 °C cavity surface temperature and different heating times. The temperature and pressure evolution of the passive test were also reported.