Skip to main content
. 2020 Feb 17;2(2):100092. doi: 10.1016/j.jhepr.2020.100092

Fig. 1.

Fig. 1

Perfusion flows and markers of liver function during 4 h of normothermic reperfusion after either 2 h, 6 h, or 24 h of DHOPE.

(A) Portal venous flow, (B) hepatic artery flow, (C) lactate concentration, (D) perfusate pH, (E) glucose levels. All livers show good liver function during reperfusion after preservation for either 2 h, 6 h, or 24 h of DHOPE. Shown here are the mean and SEM for n = 6 livers per group. There were no significant differences between the groups in all markers shown (Kruskal-Wallis test). DHOPE, dual hypothermic oxygenated machine perfusion.