Comparison 4. PFMT added to electrical stimulation versus electrical stimulation alone (excluding implanted electrodes).
Outcome or subgroup title | No. of studies | No. of participants | Statistical method | Effect size |
---|---|---|---|---|
1 Number of women cured | 1 | Risk Ratio (M‐H, Fixed, 95% CI) | Totals not selected | |
2 Number of women cured or improved | 2 | 56 | Risk Ratio (M‐H, Fixed, 95% CI) | 2.06 [0.79, 5.38] |
3 Patient satisfaction with treatment outcome | 1 | 68 | Risk Ratio (M‐H, Fixed, 95% CI) | 0.90 [0.57, 1.43] |
3.1 Immediately after treatment | 1 | 34 | Risk Ratio (M‐H, Fixed, 95% CI) | 0.84 [0.47, 1.52] |
3.2 After 12 months | 1 | 34 | Risk Ratio (M‐H, Fixed, 95% CI) | 0.99 [0.48, 2.02] |