Skip to main content
. 2020 Feb 28;20(5):1317. doi: 10.3390/s20051317

Figure 5.

Figure 5

(A) Microwell-patterned microfluidic analysis chip. Reprinted with permission from [121]. Copyright (2018), Royal Society of Chemistry. (B) Schematic illustration of the assembled chip of the MERCA system for nucleic acid detection. The microfluidic chamber is functionalized with probes to capture target miRNAs; (bottom) design of the MERCA chip. The three-layer PDMS/glass chip integrates seven units working parallelly, consisting of an assay chamber with a three-valve pump. Reprinted with permission from [123]. Copyright (2019), Science Direct. (C) Microbiochip integrating a unit for nucleic acid extraction, preconcentration and sensing. Reprinted with permission from [124]. Copyright (2015), Elsevier. (D) Principle of detection and chemical-free lysis of exosomes for an integrated microfluidic platform for miRNA analysis. Licensed under CC BY-NC 4.0 International License.