Skip to main content
. 2020 Feb 26;20(5):1271. doi: 10.3390/s20051271

Table 2.

Damage index results based on the IMF features for different sensor locations from the damaged element.

IMF Feature Nearest Second Nearest Far Farthest
DI (%) DI (%) DI (%) DI (%)
Energy 94.24 35.84 24.92 17.34
IA 62.04 51.36 31.35 16.45
Unwrapped Phase 41.80 18.90 07.55 05.10

* Intrinsic mode function (IMF), Damage index (DI), Instantaneous amplitude (IA).