Skip to main content
. 2016 Jan 5;161(4):1015–1018. doi: 10.1007/s00705-015-2738-y

Fig. 2.

Fig. 2

Sensitivity of RPA. Different amounts of CPV-2a genomic DNA were amplified by RPA (panel A) and conventional PCR (panel B). The detection limit for RPA was 10 copies/reaction. In contrast, the detection limit for conventional PCR was 100 copies/reaction. M, DNA marker; lane 1, 105 copies; lane 2, 104 copies; lane 3, 103 copies; lane 4, 102 copies; lane 5, 101 copies; lane 6, 100 copies. Five independent reactions were performed, and similar results were obtained