Table 1. Agreement by readers on the detection results of Candida species cultured on three media plates that were obtained at 24, 48 or 72 h of incubation of the plates.

Candida organisms grown in mono- or dual-species cultures Culture media plates read at the indicated times N. of overall detections N. of detections found to be in agreement and scored as Kappa coefficient (95% CI) Level of inter-reader agreement
Correct Over Under
All species (n = 18) BCG 24 h 171 108 1 18 0.53 (0.41–0.64) Moderate
CHROM 171 59 0 52 0.55 (0.47–0.64) Moderate
SDA 171 87 0 26 0.47 (0.37–0.58) Moderate
BCG 48 h 171 120 1 4 0.29 (0.15–0.43) Fair
CHROM 171 99 1 19 0.47 (0.36–0.59) Moderate
SDA 171 113 1 7 0.34 (0.22–0.48) Fair
BCG 72 h 171 126 2 0 0.25 (0.13–0.38) Fair
CHROM 171 109 1 7 0.30 (0.18–0.44) Fair
SDA 171 119 1 3 0.31 (0.19–0.43) Fair
Common species only (n = 5) BCG 24 h 15 12 1 0 0.59 (-0.04–1.30) Moderate
CHROM 15 7 0 5 0.75 (0.48–1.04) Substantial
SDA 15 12 0 0 0.20 (-0.29–0.86) Fair
BCG 48 h 15 9 1 0 0.28 (-0.43–1.16) Fair
CHROM 15 12 0 1 0.68 (0.18–1.27) Substantial
SDA 15 13 1 0 0.72 (-0.41–2.76) Substantial
BCG 72 h 15 10 1 0 0.36 (-0.41–1.37) Fair
CHROM 15 12 0 1 0.63 (-0.03–1.52) Substantial
SDA 15 13 1 0 0.72 (-0.41–2.76) Substantial
Uncommon species only (n = 13) BCG 24 h 91 53 0 15 0.59 (0.45–0.74) Moderate
CHROM 91 26 0 28 0.49 (0.37–0.61) Moderate
SDA 91 40 0 20 0.52 (0.39–0.66) Moderate
BCG 48 h 91 67 0 4 0.39 (0.18–0.62) Fair
CHROM 91 47 1 15 0.54 (0.40–0.68) Substantial
SDA 91 56 0 4 0.28 (0.11–0.46) Fair
BCG 72 h 91 71 1 0 0.33 (0.17–0.51) Fair
CHROM 91 54 1 5 0.35 (0.19–0.53) Fair
SDA 91 57 0 2 0.23 (0.08–0.38) Fair

Mycological media used for mono- or dual-species cultures of all, common or uncommon species of Candida were BCG (Candida bromcresol green), CHROM (chromogenic medium, i.e. Brilliance Candida agar) and SDA (Sabouraud dextrose agar). We calculated the kappa coefficient with 95% confidence interval (95% CI) for the comparison among the rates of correct, over or under detections (according to the definitions specified in the text). With regard to the agreement by readers, we used values greater than zero to indicate none to slight (0.01–0.20), fair (0.21–0.40), moderate (0.41–0.60), substantial (0.61–0.80) or almost perfect (0.81–1.00) levels of agreement, and values lower than/equal to zero to indicate the absence of agreement