Table 7.

Analysis of biomechanical change in rabbits implanted with polypropylene and ACTM from 24 weeks to 48 weeks.

Levene's test for equation of variance T-test for equation of means
F P value Mean difference SE difference 95% CI t P value
Tensile stress (MPa): polypropylene 48 w-24 w 0.178 0.677 1.01 0.321 0.348–1.664 3.131 0.004
Tensile stress (MPa): ACTM 48 w-24 w 0.289 0.595 1.1 0.244 0.597–1.595 4.501 <0.001
Tensile strain (%): polypropylene 48 w-24 w 0.400 0.532 0.111 1.195 −2.336–2.559 0.093 0.926
Tensile strain (%): ACTM 48 w-24 w 1.349 0.255 0.697 2.104 −3.612–5.007 0.331 0.743