Skip to main content
. 2003 Jun;13(3):141–145. doi: 10.1038/sj.cr.7290158

Table 1.

ELISA determination of antibody titers in rabbit antiserum after immunization with N1- and N2-BSA.

Coated antigen
Peptides Serum sample Neutralized with Peptide-BSA BSA
Pre-immunization None 4,000* <1,000
N1 Post-immunization BSA >128,000 1,000
Post-immunization None >128,000 128,000
Pre-immunization None 2,000 <1,000
N2 Post-immunization BSA >128,000 1,000
Post-immunization None 128,000 16,000

*The antiserum dilution were used in ELISA determination.