Table 2.

RMSE, SSIM and HFEN for various QSM reconstructions of 6 simulated ICH brains

RMSE SSIM HFEN
MEDI 27.13 ± 8.10 0.9256 ± 0.0312 20.18 ± 9.96
U-Net 64.04 ± 5.99* 0.9380 ± 0.0195 63.37 ± 8.19*
DLL2 49.06 ± 3.93* 0.9371 ± 0.0231 48.99 ± 7.05*
FINE 25.67 ± 2.79 0.9480 ± 0.0310 25.53 ± 4.15
*