Skip to main content
. Author manuscript; available in PMC: 2021 May 1.
Published in final edited form as: Neuroimage. 2020 Jan 22;211:116579. doi: 10.1016/j.neuroimage.2020.116579

Table 5.

PSNR and SSIM for complex-valued T2w test dataset reconstruction.

PSNR (dB) SSIM
TV 39.52 ± 1.66* 0.9867 ± 0.0041*
U-Net 28.75 ± 1.95* 0.9206 ± 0.0259*
DLL2 38.95 ± 2.22* 0.9853 ± 0.0062*
MoDL 43.16 ± 1.59 0.9922 ± 0.0026*
FINE 42.93 ± 2.53 0.9898 ± 0.0051
*

denotes statistical significance for the comparison between TV/U-Net/DLL2/MoDL and FINE; p < 0.05.