Table 2 –

Estimated SSM model (Eq. (2)) parameters for ovine MVAL tissue (n=3, second animal study group) using the in vivo inverse FE modeling technique, with and without consideration of the quantified pre-strains

Without the pre-strain effect (from state β2 to state βt) μm (kPa) c0 (kPa) c1
MVAL-1 3.51 0.00233 33.66
MVAL-2 4.33 0.00192 28.04
MVAL-3 2.65 0.00041 23.54
mean 3.49 0.0016 28.41
SEM 0.49 0.0006 2.93
With the pre-strain effect (from state β0 to state βt) μm (kPa) c0 (kPa) c1
MVAL-1 3.42 1.05×10−5 24.21
MVAL-2 4.52 2.81×10−6 27.23
MVAL-3 2.83 0.42×10−6 25.18
mean 3.59 3.61×10−6 25.53
SEM 0.49 3.45×10−6 0.88