Table 1. Concentration assignment of the pooled human donor reference serum from observed ECL signal.
HPV16 E6 | HPV16 E7 | HPV18 E6 | HPV18 E7 | |||||
---|---|---|---|---|---|---|---|---|
Dilution factor | ECL Signal | Assigned Concentration (AU/mL) | ECL Signal | Assigned Concentration (AU/mL) | ECL Signal | Assigned Concentration (AU/mL) | ECL Signal | Assigned Concentration (AU/mL) |
100 | 402403 | 30 | 88255 | 5 | 623159 | 50 | 315200 | 20 |
400 | 107323 | 7.5 | 23485 | 1.25 | 185969 | 12.5 | 77691 | 5 |
1600 | 28967 | 1.875 | 4541 | 0.313 | 51975 | 3.125 | 20165 | 1.250 |
6400 | 7218 | 0.469 | 956 | 0.078 | 13054 | 0.781 | 4689 | 0.313 |
25600 | 1832 | 0.117 | 330 | 0.020 | 3378 | 0.195 | 1269 | 0.078 |
102400 | 588 | 0.029 | 152 | 0.005 | 1131 | 0.049 | 369 | 0.020 |
409600 | 179 | 0.007 | 92 | 0.001 | 510 | 0.012 | 148 | 0.005 |
Blank | 62 | 91 | 316 | 54 |