Skip to main content
. 2020 Jan 20;125(4):691–700. doi: 10.1093/aob/mcaa006

Table 1.

Means, standard deviation (s.d.), and Student’s or Welch’s t-test outputs comparing sun and shade P. aquilinum frond traits. Traits are listed by P-value from smallest to largest.

Trait Abbreviation Mean ± 1 s.d. t d.f. P
Sun Shade
Stipe density (kg m−3) 330.38 ± 33.21 257.61 ± 21.66 7.340 30 3.55E-08
Specific leaf area (cm2 g−1) SLA 65.32 ± 5.17 271.54 ± 39.05 −12.825 10 1.56E-07
Stomatal density (mm−2) SD 100.97 ± 19.50 35.86 ± 4.92 9.158 14 2.75E-07
Maximum electron transport rate (µmol m−2 s−1) J MAX 167.49 ± 23.97 72.17 ± 10.97 9.566 12 5.77E-07
Maximum carboxylation rate (µmol m−2 s−1) V CMAX 82.40 ± 12.14 39.25 ± 5.49 8.568 12 1.85E-06
Minimum water potential (MPa) ψ MIN −1.83 ± 0.22 −0.74 ± 0.29 −7.48 10 2.11E-05
Vein density (mm mm−2) VD 2.93 ± 0.35 2.15 ± 0.14 5.885 14 3.97E-05
Xylem fraction (%) F X 8.81 ± 0.83 6.20 ± 0.56 6.385 10 7.99E-05
Phloem fraction (%) F P 17.15 ± 0.75 13.89 ± 1.25 5.483 10 0.0003
Leaf epidermal cell area (µm2) 3660 ± 888 6695 ± 1077 −5.325 10 0.0003
Maximum stomatal conductance (mmol m−2 s−1) g SMAX 462 ± 76 282 ± 36 5.229 10 0.0003
Leaf to xylem area ratio (m2 cm−2) A L : AX 3.94 ± 2.05 17.82 ± 5.21 −6.072 6.51 0.0007
Conduit diameter (µm) D 24.65 ± 0.78 21.67 ± 0.54 6.280 6 0.0008
Leaf specific hydraulic conductivity 105 × (kg m−1 MPa−1 s−1) K LEAF 26.78 ± 18.95 5.39 ± 3.49 5.206 7.92 0.0008
Stipe modulus of elasticity (N mm−2) MOE 6821 ± 2009 9091 ± 1658 −3.484 30 0.0015
Water potential at 88 % loss of hydraulic conductivity (MPa) P88 −2.59 ± 0.34 −2.06 ± 0.20 −3.741 14 0.0021
Water potential at turgor loss point in pinnae (MPa) Ψ TLP −2.20 ± 0.16 −1.72 ± 0.21 −3.801 8 0.0052
Intrinsic water use efficiency (µmol CO2 mol H2O−1) WUE 61.67 ± 6.59 34.13 ± 38.94 3.208 12 0.0075
Maximum osmotic water potential in pinnae (MPa) Ψ ΠMAX −1.83 ± 0.21 −1.48 ± 0.12 −3.068 8 0.0154
Pinnae modulus of elasticity (MPa) ε 18.84 ± 3.62 14.44 ± 3.79 1.965 8.78 0.0818
Water potential at 50 % loss of hydraulic conductivity (MPa) P50 −1.76 ± 0.26 −1.51 ± 0.28 −1.857 14 0.0845
Stipe modulus of rupture (N mm−2) MOR 80.29 ± 14.31 73.13 ± 13.37 1.464 30 0.1536
Percentage loss of hydraulic conductivity at midday (%) PLCmidday 44.22 ± 25.30 28.18 ± 20.05 1.4214 18 0.1723
Guard cell length (µm) 48.58 ± 2.33 49.95 ± 1.87 −1.300 13.36 0.2160
Proportion of xylem conduits filled at 0.058 m from silicone injection point ( %) 2.38 ± 0.77 3.31 ± 1.59 −1.292 10 0.2256
Hydraulic conduit diameter (µm) D H 68.68 ± 2.68 70.38 ± 1.38 −1.123 6 0.3044
Guard cell width (µm) 14.66 ± 0.63 14.08 ± 1.20 0.785 14 0.4450
Xylem-specific hydraulic conductivity (kg m−1 kPa−1 s−1) K S 21.01 ± 6.57 23.35 ± 5.07 −0.690 10 0.5059
Day respiration (µmol m−2 s−1) R D 1.22 ± 0.23 1.38 ± 1.09 −0.375 12 0.7141
Mean conduit length (m) L C 0.014 ± 0.004 0.015 ± 0.005 −0.308 10 0.7645
Proportion of xylem conduits filled at 0.118 m from silicone injection point (%) 0.52 ± 0.25 0.58 ± 0.61 −0.180 10 0.8604
Water potential at 12 % loss of hydraulic conductivity (MPa) P12 −0.89 ± 0.55 −0.93 ± 0.59 0.148 14 0.8843