Stipe density (kg m−3) |
|
330.38 ± 33.21 |
257.61 ± 21.66 |
7.340 |
30 |
3.55E-08 |
Specific leaf area (cm2 g−1) |
SLA |
65.32 ± 5.17 |
271.54 ± 39.05 |
−12.825 |
10 |
1.56E-07 |
Stomatal density (mm−2) |
SD |
100.97 ± 19.50 |
35.86 ± 4.92 |
9.158 |
14 |
2.75E-07 |
Maximum electron transport rate (µmol m−2 s−1) |
J
MAX
|
167.49 ± 23.97 |
72.17 ± 10.97 |
9.566 |
12 |
5.77E-07 |
Maximum carboxylation rate (µmol m−2 s−1) |
V
CMAX
|
82.40 ± 12.14 |
39.25 ± 5.49 |
8.568 |
12 |
1.85E-06 |
Minimum water potential (MPa) |
ψ MIN
|
−1.83 ± 0.22 |
−0.74 ± 0.29 |
−7.48 |
10 |
2.11E-05 |
Vein density (mm mm−2) |
VD |
2.93 ± 0.35 |
2.15 ± 0.14 |
5.885 |
14 |
3.97E-05 |
Xylem fraction (%) |
F
X
|
8.81 ± 0.83 |
6.20 ± 0.56 |
6.385 |
10 |
7.99E-05 |
Phloem fraction (%) |
F
P
|
17.15 ± 0.75 |
13.89 ± 1.25 |
5.483 |
10 |
0.0003 |
Leaf epidermal cell area (µm2) |
|
3660 ± 888 |
6695 ± 1077 |
−5.325 |
10 |
0.0003 |
Maximum stomatal conductance (mmol m−2 s−1) |
g
SMAX
|
462 ± 76 |
282 ± 36 |
5.229 |
10 |
0.0003 |
Leaf to xylem area ratio (m2 cm−2) |
A
L : AX
|
3.94 ± 2.05 |
17.82 ± 5.21 |
−6.072 |
6.51 |
0.0007 |
Conduit diameter (µm) |
D
|
24.65 ± 0.78 |
21.67 ± 0.54 |
6.280 |
6 |
0.0008 |
Leaf specific hydraulic conductivity 105 × (kg m−1 MPa−1 s−1) |
K
LEAF
|
26.78 ± 18.95 |
5.39 ± 3.49 |
5.206 |
7.92 |
0.0008 |
Stipe modulus of elasticity (N mm−2) |
MOE |
6821 ± 2009 |
9091 ± 1658 |
−3.484 |
30 |
0.0015 |
Water potential at 88 % loss of hydraulic conductivity (MPa) |
P88
|
−2.59 ± 0.34 |
−2.06 ± 0.20 |
−3.741 |
14 |
0.0021 |
Water potential at turgor loss point in pinnae (MPa) |
Ψ TLP
|
−2.20 ± 0.16 |
−1.72 ± 0.21 |
−3.801 |
8 |
0.0052 |
Intrinsic water use efficiency (µmol CO2 mol H2O−1) |
WUE |
61.67 ± 6.59 |
34.13 ± 38.94 |
3.208 |
12 |
0.0075 |
Maximum osmotic water potential in pinnae (MPa) |
Ψ ΠMAX
|
−1.83 ± 0.21 |
−1.48 ± 0.12 |
−3.068 |
8 |
0.0154 |
Pinnae modulus of elasticity (MPa) |
ε |
18.84 ± 3.62 |
14.44 ± 3.79 |
1.965 |
8.78 |
0.0818 |
Water potential at 50 % loss of hydraulic conductivity (MPa) |
P50
|
−1.76 ± 0.26 |
−1.51 ± 0.28 |
−1.857 |
14 |
0.0845 |
Stipe modulus of rupture (N mm−2) |
MOR |
80.29 ± 14.31 |
73.13 ± 13.37 |
1.464 |
30 |
0.1536 |
Percentage loss of hydraulic conductivity at midday (%) |
PLCmidday
|
44.22 ± 25.30 |
28.18 ± 20.05 |
1.4214 |
18 |
0.1723 |
Guard cell length (µm) |
|
48.58 ± 2.33 |
49.95 ± 1.87 |
−1.300 |
13.36 |
0.2160 |
Proportion of xylem conduits filled at 0.058 m from silicone injection point ( %) |
|
2.38 ± 0.77 |
3.31 ± 1.59 |
−1.292 |
10 |
0.2256 |
Hydraulic conduit diameter (µm) |
D
H
|
68.68 ± 2.68 |
70.38 ± 1.38 |
−1.123 |
6 |
0.3044 |
Guard cell width (µm) |
|
14.66 ± 0.63 |
14.08 ± 1.20 |
0.785 |
14 |
0.4450 |
Xylem-specific hydraulic conductivity (kg m−1 kPa−1 s−1) |
K
S
|
21.01 ± 6.57 |
23.35 ± 5.07 |
−0.690 |
10 |
0.5059 |
Day respiration (µmol m−2 s−1) |
R
D
|
1.22 ± 0.23 |
1.38 ± 1.09 |
−0.375 |
12 |
0.7141 |
Mean conduit length (m) |
L
C
|
0.014 ± 0.004 |
0.015 ± 0.005 |
−0.308 |
10 |
0.7645 |
Proportion of xylem conduits filled at 0.118 m from silicone injection point (%) |
|
0.52 ± 0.25 |
0.58 ± 0.61 |
−0.180 |
10 |
0.8604 |
Water potential at 12 % loss of hydraulic conductivity (MPa) |
P12
|
−0.89 ± 0.55 |
−0.93 ± 0.59 |
0.148 |
14 |
0.8843 |