Skip to main content
. Author manuscript; available in PMC: 2020 Mar 29.
Published in final edited form as: Conf Proc IEEE Eng Med Biol Soc. 2018 Jul;2018:1–4. doi: 10.1109/EMBC.2018.8513070

Table 7.

Confusion matrix for 3D-CNN.

Imaging Node Predicted Normal Predicted Suspicious Predicted Involved UA
Normal 15 2 0 0.88
CT Suspicious 1 20 6 0.74
Involved 1 1 20 0.91
PA 0.88 0.87 0.77
Normal 16 1 0 0.94
PET Suspicious 5 18 4 0.67
Involved 2 2 18 0.82
PA 0.70 0.86 0.82
Normal 16 1 0 0.94
PET & CT Suspicious 2 23 2 0.85
Involved 1 2 19 0.86
PA 0.84 0.88 0.90