. 2015 Oct 11;17(6):722–728. doi: 10.1016/j.jmoldx.2015.06.008

Table 3.

Performance of Real-Time RT-PCR Assay on Serum Specimens

Type of serum samples No. of samples No. of samples correctly serotyped Serotyping sensitivity, % (95% CI) Detection sensitivity, % (95% CI) Detection specificity, % (95% CI)
DENV-1 29 26 89.66 (71.50– 97.29) 100 (93.58–100) 100 (85.87–100)
DENV-2 30 29 96.67 (80.95– 99.83)
DENV-3 30 29 96.67 (80.95– 99.83)
DENV-4 17 16 94.12 (69.24– 99.69)
CHIKV 47 45 95.74 (84.27–99.26) 100 (85.87–100)
Healthy samples 30 0

Number of specimens with correct serotype detected/(number of specimens with correct serotype detected + number of specimens with wrong serotype detected) × 100%.

Number of positive specimens/(number of positive specimens + number of false-negative specimens) × 100%.

Number of negative specimens/(number of negative specimens + number of false-positive specimens) × 100%.