Skip to main content
. 2020 Mar 31;6(2):e62–e66. doi: 10.1055/s-0040-1705171

Table 2. Short-term adverse events of e-TREPP for strangulated inguinal hernia repair.

n  = 33
Short-term (<30 d):
 Mortality a 1
 Wound infection 1
 Abscess 1
 Mesh removal 1
 Bleeding 0
 Hematoma 2
 Early recurrence 1
 Ileus (reoperation needed) 1

Abbreviation: e-TREPP, emergency TransREctus sheath Pre-Peritoneal.

a

Caused by massive aspiration followed by absence of cardiac activity.