Skip to main content
. 2020 Mar 31;10:5729. doi: 10.1038/s41598-020-62617-4

Table 3.

λΩ21/2, ∫g(E)EdE, ωln, TC,calADMM calculated for all samples, using μ* = 0.117 and TC,calE calculated for all samples, using μ* = 0.119. The last column shows the experimentally obtained critical temperature, TC,exp *(the error on TC,exp is 0.05 K for all samples and is determined by the temperature stability of the SQUID magnetometer, the errors indicated for the other quantities are based on the statistical error of the PDOS).

Sample λ Ω21/2 g(E)EdE ωln TC,calADMM TC,calE TC,exp*
(meV) (meV) (meV) (K) (K) (K)
119Sn foil 0.76 ± 0.04 10.4 ± 0.2 11.62 ± 0.03 8.1 ± 0.2 3.7 ± 0.2 3.7 ± 0.2 3.85
isl60 0.82 ± 0.03 9.9 ± 0.3 10.82 ± 0.04 7.8 ± 0.2 4.1 ± 0.2 4.2 ± 0.2 4.17
isl40 0.84 ± 0.06 9.8 ± 0.4 10.74 ± 0.05 7.6 ± 0.3 4.3 ± 0.4 4.4 ± 0.3 4.38
clus46 0.82 ± 0.04 9.8 ± 0.3 10.36 ± 0.03 7.6 ± 0.2 4.1 ± 0.2 4.1 ± 0.2 3.93