Test AUC p AUC 95% CI Cutoff value Sensitivity (%) Specificity (%)
Lower limit Upper limit
QFT 0.851 <0.001 0.799 0.903 0.55 86.30 80.00
ESR 0.686 <0.001 0.612 0.759 16.50 84.93 47.41
Serum ADA 0.726 <0.001 0.653 0.800 15.31 73.97 74.81
Serum CA125 0.723 <0.001 0.653 0.793 30.34 84.93 60.00
hs-CRP 0.802 <0.001 0.736 0.867 43.54 68.49 85.19
Ascitic ADA 0.932 0.034 0.866 0.998 24.06 90.00 96.77
Ascitic CA125 0.649 0.032 0.521 0.777 873.15 65.00 61.29

Note: Comparison of AUCs of ESR, serum ADA, serum CA125, and hs-CRP with QFT AUC, p < 0.05. Comparison of AUCs of ascitic ADA with ascitic CA125, p < 0.05. AUC: area under the curve; QFT: Quanti FERON-TB; ESR: erythrocyte sedimentation rate; ADA: adenosine deaminase; CA125: cancer antigen 125; hs-CRP: high-sensitivity C-reactive protein.