Fig. 2.

Fig. 2

Schematic representation of the tangential flow filtration (TFF) system used in the present study. (A) The system was manually controlled by using the pump output and adjustable valves 2 and 3 (V2 and V3) with modulating transmembrane pressure (TMP). TMP is the difference between the pressure upstream (applied pressure) and downstream (permeate) of the membrane, and is calculated using the equation TMP = [Pfeed (P1) + Pretentate (P2)]/2 − Ppermeate (P3). The three pressure indicators are labeled as P1, P2 and P3. (B) Characterization of the membrane. The permeate flow (flux) of E. coli cell culture (OD600, ∼3.0) was measured by setting delta-P (P1 − P2) at 0.1 MPa and altering TMP in the range of 0–0.13 MPa.