Table 6.
Absolute quantification strategies.
| Organism | Target | Sample | Kit/extra reagents | Amplification device | Transduction | Detection Platform | Amp. time (min) | T (ºC) | LOD | Ref. |
|---|---|---|---|---|---|---|---|---|---|---|
| MRSA | dsDNA | Genomic DNA | TwistAmp Exo kit | SlipChip + plate reader | Fluorescence | Plate reader | 30 | 39 | 300 copies/ml | [134] |
| MRSA | dsDNA | Genomic DNA spiked in blood | TwistAmp Exo kit | Microfluidic chip, digital plasma separation, incubator | Fluorescence | Fluorescence microscope | 30 | 37 | 1000 copies/ml | [20] |
| Listeria monocytogenes | dsDNA | Certified DNA | TwistAmp Nfo kit | Centrifugal heater with an integrated fluorimeter | Fluorescence | Centrifugal heater with an integrated fluorimeter | 30 | 39 | – | [133] |
| Listeria monocytogenes | dsDNA | Genomic DNA | TwistAmp Exo kit | Picoliter array chip | Fluorescence | Modified fluorescence microscope | 15 | 39 | 4·10−3 copies/well | [135] |