Percentage of positive samples by different diagnostics assays.

Animal species Assays
EM ELISAa Commercial RT-iiPCR Commercial real-time rtRT-PCR kitb In-house rtRT-PCR assay
Bovine 21/68 (30.9%) 20/54 (37%) 54/76 (71%) 52/76 (68.4%) 35/76 (46%)
Equine 1/6 (16.7%) 2/21 (9.5%) 3/22 (13.6%) 2/22 (9.1%) 2/22 (9.1%)
Caprine 1/4 (25%) 0/4 (0%) 1/4 (25%) 0/4 (0%) 0/4 (0%)
Canine 3/6 (50%) 3/6 (50%) 4/6 (66.7%) 3/6 (50%) 3/6 (50%)
Total 26/84 (31%) 25/85 (29.4%) 62/108 (57.4%) 57/108 (52.8%) 40/108 (37%)
a

Premier™ Rotaclone ELISA kit, Meridian Bioscience, USA.