. 2020 Jan 21;28(2):109–120. doi: 10.4250/jcvi.2019.0094

Table 3. Effect of CRT on right ventriculo-arterial coupling variables.

Variables CRT non-responders CRT responders
Baseline CRT Confidence Interval p value Baseline CRT Confidence Interval p value
TAPSE (mm) 14.8 ± 3.2 15.5 ± 5.2 0.580 16.2 ± 3.4 19.0 ± 4.6 0.020
PASP (mmHg) 45.4 ± 14.9 38.9 ± 13.8 0.154 32.2 ± 11.6 28.7 ± 8.6 0.265
TAPSE/PASP 0.37 ± 0.17 0.43 ± 0.19 0.249 0.56 ± 0.21 0.72 ± 0.3 0.037

Data was grouped according to non-responders (Δ LVEF < 5%) and responders (Δ LVEF ≥ 5%) to CRT.

Data are presented as mean ± standard deviation.

CRT: cardiac resynchronization therapy, PASP: pulmonary artery systolic pressure, TAPSE: tricuspid annular plane systolic excursion.

Statistical significance between groups was calculated using Student's t-test. A p value < 0.05 was considered significant.