Table 1. UV–Visible Absorption and Steady-State Fluorescence Peak Maxima of C-490 in Pure Water, n-Propanol, Bulk Solvent (CYH + Prop), and in Reverse Micellar Systems with Varying Wo.
systems | λmaxabs (nm) | λmaxflu* (nm) | λmaxflu# (nm) | λmaxflu$ (nm) | λmaxabs (nm) | λmaxflu* (nm) | λmaxflu# (nm) | λmaxflu$ (nm) | λmaxabs (nm) | λmaxflu* (nm) | λmaxflu# (nm) | λmaxflu$ (nm) |
---|---|---|---|---|---|---|---|---|---|---|---|---|
water | 366 | 491 | 491 | 492 | ||||||||
bulk solvent | 373 | 467 | 467 | 467 | ||||||||
n-propanol | 383 | 476 | 476 | 479 |
12-5-12 | 12-6-12 | 12-8-12 | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wo = 2 | 383 | 474 | 473 | 474 | 384 | 474 | 473 | 474 | 384 | 476 | 473 | 475 |
Wo = 5 | 383 | 474 | 474 | 475 | 383 | 474 | 474 | 475 | 384 | 475 | 474 | 477 |
Wo = 10 | 382 | 475 | 475 | 475 | 383 | 475 | 475 | 475 | 383 | 476 | 474 | 477 |
Wo = 15 | 382 | 476 | 476 | 478 | 382 | 477 | 476 | 478 | 383 | 477 | 474 | 477 |
Wo = 20 | 381 | 477 | 476 | 478 | 382 | 477 | 476 | 478 | 382 | 477 | 475 | 478 |
Wo = 25 | 381 | 478 | 477 | 478 | 380 | 478 | 477 | 478 | 382 | 477 | 476 | 478 |
λexc = 340 nm. #λexc = 375 nm. $λexc = 412 nm.