Table 2. Isotherm Parameters for Cr(VI) Adsorption onto PPy/MLS at 25, 35, and 45 °C.
| Langmuir
model |
Freundlich
model |
||||||
|---|---|---|---|---|---|---|---|
| T (K) | b | Qm | R2 | RL | KF | 1/n | R2 |
| 298 | 0.590 | 343.64 | 0.999 | 0.0635 | 176.23 | 0.141 | 0.825 |
| 308 | 1.125 | 389.11 | 0.999 | 0.0175 | 263.94 | 0.093 | 0.837 |
| 318 | 2.178 | 429.18 | 0.999 | 0.00608 | 295.62 | 0.092 | 0.789 |