Table 1.

Summary of air-exchange and outdoor air proportion measurements

Location Volume, m3 N Total ACH, mean ± SD MSE Outdoor air proportion Precision, % Mean outdoor ACH§ Outdoor air, m3/h
Lung Function Laboratory 168.5 3 8.5 ± 0.8 0.03 0.57 25.3 4.9 817.4
ED isolation room 23.5 3 23.8 ± 1.5 0.16 1.0 23.8 559.7
Consulting room A (closed) 31.5 3 7.0 ± 0.1 0.01 0.28 14.2 2.0 62
Consulting room A (open) 3 13.2 ± 1.1 0.06 3.7 117.3
Consulting room B (closed) 36.0 3 6.1 ± 0.1 0.01 0.28 14.2 1.7 62.1
Consulting room B (open) 3 9.1 ± 1.1 0.02 2.6 92.6

Number of ventilation measurements.

Mean standard error of line fit to CO2 decays.

Precision of outdoor air proportion measurement.17

§

The number of outdoor ACH was equal to the measured ACH rate multiplied by the proportion of outdoor air supplied.