Results of operator skill level classification with different models using motion data when scanning the brain. “EX” and “NQ” denotes expert and newly qualified respectively. “Macro” and “Weighted” refers to the mean and weighted mean for each evaluation metric.

Precision Recall F1 Score Accuracy
1D ResNet18 EX 0.88 0.71 0.79 0.85
NQ 0.83 0.94 0.88
Macro 0.86 0.82 0.83
Weighted 0.85 0.85 0.84
1D ResNet 18
with operator loss
EX 0.91 0.97 0.94 0.95
NQ 0.98 0.94 0.96
Macro 0.94 0.95 0.95
Weighted 0.95 0.95 0.95
SVM EX 0.67 0.65 0.66 0.75
NQ 0.80 0.81 0.80
Macro 0.73 0.73 0.73
Weighted 0.75 0.75 0.75