Table 3. Details of reasons for failing the follow-up survey test in the last five years.

RPE category Failure reason
2018 Dust mask ·Insufficient tensile strength of the strap
·Missing of the pass certificate ravel
Gas mask ·Failing to meet the exhaust resistance criteria
·Failing to meet the intake resistance criteria
·Failing to meet the air tightness criteria

2017 Dust mask ·Failing to meet the capture efficiency criteria
·Incorrect description of the manual and/or attached documents
PAPR ·Incorrect description of the manual and/or attached documents

2016 Dust mask ·Incorrect description of the manual and/or attached documents
PAPR ·Incorrect description of the manual and/or attached documents

2015 Dust mask ·Insufficient tensile strength of the strap
·Missing of the manual
Gas mask ·Insufficient decontamination performance of the canister

2014 Dust mask ·Insufficient tensile strength of the strap
·Failing to meet the air tightness criteria
Gas mask ·Incorrect description of the manual and/or attached documents

RPE: respiratory protective equipment; PAPR: powered air-purifying respirators.