Skip to main content
. 2020 Mar 27;11:408. doi: 10.3389/fmicb.2020.00408

TABLE 1.

Selected examples of aptasensors for detection of AFB1.

Detection methods Aptamer sequence (5′–3′) LOD Linear range References
Fluorescence GTT GGG CAC GTG TTG TCT CTC TGT GTC TCG TGC CCT TCG CTA GGCCC 20 pg/mL 0.05–100 ng/mL Lu et al., 2019
GT TGG GCA CGT GTT GTC TCT CTG TGT CTC GTG CCC TTC GCT AGG CCC ACA 0.3 pg/mL 5–1000 pg/mL Nasirian et al., 2017
AAA AAA AAG TTG GGC ACG TGT TGT CTC TCT GTG TCT CGT GCC CTT CGC TAG GCC CAC AC 70 pg/mL 0.1–0.8 ng/mL Li Z. et al., 2019
ATA TCT TTT CCT ACT CAT CTT TGA ATA ACT ACC GGG CAT TAC TTT CTG GCC TCC CTG CCT CCT AAA TCA CCA ATT AAT TCG CGG CCC CCC G 4 ng/mL 0.002–0.2 μg/mL Kumar et al., 2018
Colorimetry GTT GGG CAC GTG TTG TCT CTC TGT GTC TCG TGC CCT TCG CTA GGC CC 1 pM Wu et al., 2019a
SERS GTTGG GCA CGT GTT GTC TCT CTG TGT CTC GTG CCC TTC GCT AGG CCC 3.6 pg/mL 0.01–100 ng/mL Chen et al., 2018
GTTGG GCA CGT GTT GTC TCT CTG TGT CTC GTG CCC TTC GCT AGG CCC 0.54 pg/mL 0.001–10 ng/mL Yang et al., 2017
SPR TGG GCA CGT GTT GTC TCT CTG TGT CTC GTG CCC T 0.4 nM 0.4–200 nM Sun et al., 2017
GTT GGG CAC GTG TTG TCT CTC TGT GTC TCG TGC CCT TCG CTA GGC CCA CA 0.19 ng/mL 1.5–50 ng/mL Wu et al., 2018
Electrochemistry GTT GGG CAC GTG TTG TCT CTC TGT GTC TCG TGC CCT TCG CTA GGC CCA CA 0.01 fg/mL 0.1 fg/mL-0.1 μg/mL Peng et al., 2018
GTT GGG CAC GTG TTG TCT CTC TGT GTC TCG TGC CCT TCG CTA GGC CCA CA 86 fg/mL 0.1–10 ng/mL Selvolini et al., 2019
GTT GGG CAC GTG TTG TCT CTC TGT GTC TCG TGC CCT TCG CTA GGC CCA CA 0.13 ng/mL 1-20 ng/mL Mo et al., 2018