Skip to main content
. 2003 Feb 18;109(1):39–45. doi: 10.1016/S0166-0934(03)00042-9

Table 3.

Comparison of the techniques used to detect RSV in infected MRC5 cells

Dilutiona Qualitative RT-PCR hybridisation-EIA Culture Real-time RT-PCR assay for RSV
RSV A long 10−5 + + +
10−6 + +



RSV B1 10−4 + + +
10−5 + +
10−6



RSV A wt no. 1 10−4 + + +
10−5 + +
10−6 +



RSV A wt no. 2 10−5 + + +
10−6 +



RSV B wt 10−5 + + +
10−6 +
a

The other tested dilutions were all positive (i.e. 10−3 or 10−4) or all negative (i.e. 10−7).