TABLE VI:

The 50th percentile phase velocity of the inclusion for Model DL and various LPVI processing scenarios. Values are presented in the unit of m/s.

Noise level [dB] Processing Frequency [Hz]
500 600 700 800 900 1000
No noise I 1.65 1.68 1.71 1.74 1.76 1.80
II 1.64 1.68 1.70 1.74 1.77 1.79
III 1.65 1.69 1.73 1.73 1.76 1.80
IV 1.65 1.69 1.73 1.73 1.76 1.80
V 1.63 1.70 1.72 1.72 1.77 1.80
VI 1.63 1.70 1.72 1.72 1.77 1.80

20 I 1.65 1.68 1.71 1.71 1.69 1.68
II 1.64 1.68 1.70 1.74 1.76 1.80
III 1.65 1.69 1.73 1.72 1.76 1.80
IV 1.65 1.69 1.73 1.72 1.76 1.80
V 1.63 1.70 1.71 1.72 1.77 1.78
VI 1.63 1.70 1.72 1.72 1.77 1.80

15 I 1.64 1.68 1.70 1.63 1.50 1.31
II 1.64 1.68 1.70 1.74 1.76 1.80
III 1.65 1.69 1.72 1.72 1.75 1.79
IV 1.65 1.69 1.73 1.73 1.76 1.80
V 1.63 1.70 1.72 1.73 1.77 1.73
VI 1.63 1.69 1.72 1.73 1.77 1.79

10 I 1.62 1.66 1.58 1.31 1.07 0.69
II 1.65 1.68 1.71 1.74 1.76 1.79
III 1.64 1.69 1.73 1.70 1.70 1.67
IV 1.65 1.69 1.73 1.72 1.76 1.80
V 1.63 1.70 1.70 1.65 1.67 1.61
VI 1.63 1.70 1.72 1.72 1.77 1.79

5 I 1.54 1.44 1.05 0.70 0.41 0.33
II 1.64 1.68 1.71 1.74 1.75 1.77
III 1.65 1.69 1.71 1.59 1.55 1.45
IV 1.65 1.69 1.73 1.72 1.76 1.80
V 1.63 1.69 1.67 1.48 1.42 1.19
VI 1.63 1.70 1.72 1.72 1.76 1.79