Skip to main content
. 2015 Aug 5;83(4):400–406. doi: 10.1016/j.diagmicrobio.2015.08.001

Table 3.

Comparison of potential etiologic pathogens detected by PPMC standard diagnostic bundle or diagnostic bundle with FilmArray multiplex PCR substituted for PPMC viral PCR respiratory virus panel.

Pathogen identified Standard (24 patients) FilmArray (22 patients)
Patients with viral pathogen only
 Adenovirus 0 1
 Coronavirus 0 5
 Human metapneumovirus 3 2
 Influenza 3 0
 Parainfluenza 0 0
 Respiratory syncytial virus 1 3
 Rhinovirus 0 0
Patients with bacterial pathogen only
 Streptococcus anginosus 1 0
 S. pneumoniae 5 2
 S. pneumoniae + MRSA 0 1
 Streptococcus pneumoniae + MSSA 1 0
 MRSA only 2 0
 C. pneumoniae 1
 L. pneumophila 1 0
Patients with both viral and bacterial pathogens
 Influenza + elevated PCT 3
 S. pneumoniae + influenza 0 0
 S. pneumoniae + adenovirus 1 1
 S. pneumoniae + hMPV 1 1
 S. pneumoniae + rhinovirus 0 1
 S. pneumoniae + RSV 1 1
 MRSA + hMPV 1
 M. catarrhalis + coronavirus 1
 MRSA + RSV 1