Skip to main content
. 2015 Aug 31;29(6):408–413. doi: 10.1016/j.mcp.2015.08.006

Table 5.

Intra-assay and inter-assay variability of the results of the 6 duplex PCR assays performed with the positive controls (mean of the melting temperature of each amplicon ± standard deviation).

Target Intra-assay variability Inter-assay variability
Influenza A 82.65 ± 0.04 82.78 ± 0.33
Influenza B 78.18 ± 0.07 78.08 ± 0.09
PIV2 74.10 ± 0.04 74.22 ± 0.40
hMPV 80.50 ± 0.05 80.10 ± 0.50
CoVI 229E 76.40 ± 0.12 76.35 ± 0.37
CoVI NL63 75.70 ± 0.07 75.83 ± 0.06
EV 85.88 ± 0.14 85.90 ± 0.28
hRV 84.35 ± 0.12 84.28 ± 0.25
PIV1 and 3 73.05 ± 0.05 73.02 ± 0.20
hRSV 76.88 ± 0.12 76.93 ± 0.62
CoVII OC43 77.5 ± 0.02 77.2 ± 0.2
PIV4 80.05 ± 0.12 80.02 ± 0.50
hAdV 83.98 ± 0.02 84.07 ± 0.25
HBoV 77.7 ± 0.2 78.02 ± 0.33