Skip to main content
. 2020 Mar 9;36(2):215–270. doi: 10.1002/joa3.12308

Table 10‐1.

Consensus recommendations

Use of 3D mapping in ventricular tachycardia: Idiopathic outflow tract tachycardia
Recommendation Class LOE References
In pediatric or pregnant patients, 3D mapping systems are recommended to avoid or minimize radiation exposure. I C‐LD 249, 251
Due to the complex anatomy of the outflow tract, the primary use of a 3D mapping system is recommended in all OT‐VT that do not stem from the RVOT. I C‐LD 256, 260
In case of recurrent RVOT‐VT the use of a 3D mapping system is reasonable. IIa C‐EO  

3D, three‐dimensional; OT, outflow tract; RVOT, right ventricular outflow tract; VT, ventricular tachycardia.