Table 5.
Study sites | Sensitivity % (95% CI) | Specificity % (95% CI) | PPV % (95% CI) | NPV % (95% CI) |
---|---|---|---|---|
Panel A – Site-specific accuracy of the algorithm achieving the highest overall PPV (Algorithm 6) | ||||
UHC A | 61.5 (54.3–68.7) | 88.9 (85.3–92.4) | 75.9 (68.8–83.0) | 80.2 (75.9–84.4) |
UHC B | 78.7 (72.1–85.2) | 85.9 (82.2–89.5) | 70.7 (63.8–77.6) | 90.3 (87.1–93.5) |
Panel B – Site-specific accuracy of the algorithm achieving highest overall sensitivity (Algorithm 5) | ||||
UHC A | 62.6 (55.5–69.8) | 87.9 (84.2–91.5) | 74.6 (67.6–81.7) | 80.5 (76.2–84.7) |
UHC B | 79.3 (72.9–85.8) | 84.4 (80.6–88.3) | 68.8 (61.9–75.7) | 90.4 (87.2–93.6) |
Abbreviations: CI Confidence interval, PPV Positive predictive value, NPV Negative predictive value