Skip to main content
. 2020 Apr 7;7:17. doi: 10.1186/s40662-020-00186-3

Table 3.

Influence of MfIOL placement on vertical decentration among non-myopic and myopic eyes

Placement Non-Myopic: Axial length ≤ 24.5 mm Myopic: Axial length > 24.5 mm
Group A
(n = 30)
Group B
(n = 28)
P value* Group A
(n = 33)
Group B
(n = 31)
P value*
Na Vertical decentration (mm) Na Vertical decentration (mm) Na Vertical decentration (mm) Na Vertical decentration (mm)
Horizontal 7 −0.03 ± 0.06 6 − 0.13 ± 0.20 0.229 6 − 0.03 ± 0.10 9 −0.22 ± 0.11 0.005
Vertical 5 0.00 ± 0.06 7 −0.02 ± 0.20 0.823 6 −0.03 ± 0.07 6 −0.07 ± 0.13 0.537
Oblique 18 −0.03 ± 0.09 15 − 0.06 ± 0.09 0.289 21 −0.03 ± 0.10 16 −0.17 ± 0.14 0.001

MfIOL = Multifocal intraocular lens

Data are mean ± standard deviation

* P values < 0.05 were considered statistically significant. Student’s t-test

aN = Number of eyes