Skip to main content
. 2020 Mar 21;13(6):1436. doi: 10.3390/ma13061436

Table 2.

Results of numerical computation of the thickness of a corrosion-damaged region on the plate (laser intensity = 4.0%).

Artificial Corrosion Depth Weighted Average Thickness (2h) Predicted Corrosion Depth
0.5 mm 2.442 mm 0.558 mm
1.0 mm 1.864 mm 1.136 mm
1.5 mm 1.555 mm 1.445 mm
2.0 mm 1.159 mm 1.841 mm