Skip to main content
. 2020 Mar 21;13(6):1436. doi: 10.3390/ma13061436

Table 3.

Results of numerical computation of the thickness of a corrosion-damaged region on the plate (laser intensity = 5.0%).

Artificial Corrosion Depth Weighted Average Thickness (2h) Predicted Corrosion Depth
0.5 mm 2.470 mm 0.530 mm
1.0 mm 1.827 mm 1.173 mm
1.5 mm 1.530 mm 1.470 mm
2.0 mm 1.151 mm 1.849 mm