Skip to main content
. 2019 Aug 19;4(2):185–190. doi: 10.1002/jgh3.12247

Table 3.

Comparisons between balloon‐assisted endoscope (group B) and conventional endoscope (group C) groups according to colonic location

Location (n) P
Group B (n = 22) Group C (n = 15)
C, A (37) Duration of ESD procedure (median; min) (range) 66.5 (7–250) 102 (12–165) 0.27
Dissection speed (median; mm2/min) (range) 22.3 (8–51) 11.3 (4–43) 0.037
Group B (n = 32) Group C (n = 14)
T, D (46) Duration of ESD procedure (median; min) (range) 42 (16–218) 41 (15–150) 0.84
Dissection speed (median; mm2/min) (range) 18.4 (5–45.7) 20.6 (4.5–40) >0.99

Mann–Whitney U test.

A, ascending colon; C, cecum; D, descending colon; ESD, endoscopic submucosal dissection; T, transverse colon.