Skip to main content
. 2020 Apr 3;7:105. doi: 10.3389/fmed.2020.00105

Table 3.

ASV ventilator settings (n = 458), interfaces, humidifiers, and oxygen supplementation.

A. Interfaces, humidifier, and oxygen supplementation (n, %) Missing data
Interfaces 2
- Facial masks
- Nasal masks
- Nasal pillows
318 (70)
- 93 (20)
- 45 (10)
Humidifier 314 (69) 1
Oxygen supplementation during ASV 16 (3.5)
B. Ventilator settings (ASV)
ResMed® devices** Philips respironics® and lowenstein® devices§
All values are median (IQR) n = 409 n = 49*
Minimal pressure support (cmH2O) 3 (3; 3) 0 (0; 3)
Maximal pressure support (cmH2O) 10 (10; 12) 10 (8; 15)
Fixed EPAP n = 284 n = 5
Fixed EPAP (cmH2O) 6 (5; 8) 9 (8; 10)
Variable EPAP n = 115 n = 43
Minimal EPAP (cmH2O) 5 (4; 7.5) 6 (4; 9.7)
Maximal EPAP (cmH2O) 11 (10; 14) 12 (10; 14.5)
Back-up respiratory rate (Cycles/min) 12 (12; 13.7)
Missing data 10 1

EPAP: Expiratory positive airway pressure.

**

See text for details. Default EPAP value set at 3 cmH2O.

§

See text for details. Default EPAP value set at 0 cmH2O.

*

26 patients in “Auto” mode for back-up respiratory rate.