Table 1.
Examiner | Methods | Sensitivity | Specificity | Az of ROC | ||||
---|---|---|---|---|---|---|---|---|
0 Versus 1–3 | 0–1 Versus 2–3 | 0–2 Versus 3 | 0 Versus 1–3 | 0–1 Versus 2–3 | 0–2 Versus 3 | |||
1 | OCT | 1.000 | 0.788 | 0.818 | 0.667 | 0.667 | 0.769 | 0.849 |
X-ray | 0.917 | 0.697 | 0.727 | 0.600 | 0.700 | 0.731 | 0.819 | |
2 | OCT | 0.979 | 0.939 | 0.909 | 0.800 | 0.633 | 0.596 | 0.751 |
X-ray | 0.896 | 0.909 | 0.818 | 0.800 | 0.633 | 0.654 | 0.745 | |
3 | OCT | 0.917 | 0.788 | 0.909 | 0.933 | 0.833 | 0.923 | 0.943 |
X-ray | 0.833 | 0.545 | 0.545 | 1.000 | 0.800 | 0.885 | 0.788 | |
4 | OCT | 0.958 | 0.667 | 0.545 | 0.600 | 0.667 | 0.942 | 0.802 |
X-ray | 0.875 | 0.576 | 0.364 | 0.800 | 0.767 | 0.962 | 0.787 | |
5 | OCT | 1.000 | 0.939 | 0.727 | 0.867 | 0.700 | 0.769 | 0.782 |
X-ray | 1.000 | 0.818 | 0.727 | 0.800 | 0.633 | 0.808 | 0.813 | |
6 | OCT | 0.917 | 0.697 | 0.909 | 0.867 | 0.767 | 0.846 | 0.905 |
X-ray | 0.521 | 0.394 | 0.455 | 0.867 | 0.933 | 0.942 | 0.798 | |
7 | OCT | 1.000 | 0.788 | 0.455 | 0.667 | 0.667 | 0.981 | 0.862 |
X-ray | 1.000 | 0.697 | 0.455 | 0.333 | 0.733 | 0.942 | 0.879 | |
8 | OCT | 0.833 | 0.636 | 0.364 | 1.000 | 0.933 | 0.962 | 0.845 |
X-ray | 0.792 | 0.545 | 0.636 | 1.000 | 0.900 | 0.962 | 0.836 | |
9 | OCT | 0.958 | 0.879 | 0.818 | 1.000 | 0.933 | 0.904 | 0.915 |
X-ray | 0.917 | 0.788 | 0.727 | 0.867 | 0.733 | 0.808 | 0.853 | |
10 | OCT | 0.771 | 0.636 | 0.364 | 0.867 | 0.900 | 0.981 | 0.848 |
X-ray | 0.833 | 0.424 | 0.455 | 1.000 | 0.867 | 0.962 | 0.818 | |
11 | OCT | 1.000 | 0.848 | 0.909 | 0.733 | 0.600 | 0.731 | 0.837 |
X-ray | 0.917 | 0.727 | 0.636 | 1.000 | 0.767 | 0.827 | 0.844 | |
12 | OCT | 0.979 | 0.879 | 0.909 | 0.733 | 0.700 | 0.865 | 0.879 |
X-ray | 0.896 | 0.818 | 0.545 | 0.867 | 0.667 | 0.885 | 0.781 | |
13 | OCT | 0.979 | 0.758 | 1.000 | 1.000 | 0.933 | 0.885 | 0.951 |
X-ray | 0.958 | 0.424 | 0.182 | 1.000 | 0.833 | 0.942 | 0.764 | |
Average (SD) | OCT | 0.946 a (0.068) |
0.788 c (0.102) |
0.741 e (0.219) |
0.826 g (0.132)a |
0.764 h (0.120) |
0.885 k (0.109) |
0.859 m (0.057) |
X-ray | 0.873 b (0.118) |
0.643 d (0.163) |
0.559 f (0.170) |
0.841 g (0.186) |
0.767 h (0.093) |
0.870 k (0.095) |
0.810 n (0.030) |
Notes: Cutoff values: a significant difference was observed in sensitivity and area under receiver operating characteristic (ROC) curve (Az) between optical coherence tomography (OCT) and radiography (p< 0.05), whereas no such difference in specificity was shown. Different superscripts letters indicated significant difference.