Table 1.

Cutoff values: a significant difference was observed in sensitivity and Az value receiver operating characteristic (ROC) curve between OCT and radiography (p < 0.05), whereas no such difference in specificity was shown. Different superscripts letters indicated significant difference.

Examiner Methods Sensitivity Specificity Az of ROC
0 Versus 1–3 0–1 Versus 2–3 0–2 Versus 3 0 Versus 1–3 0–1 Versus 2–3 0–2 Versus 3
1 OCT 1.000 0.788 0.818 0.667 0.667 0.769 0.849
X-ray 0.917 0.697 0.727 0.600 0.700 0.731 0.819
2 OCT 0.979 0.939 0.909 0.800 0.633 0.596 0.751
X-ray 0.896 0.909 0.818 0.800 0.633 0.654 0.745
3 OCT 0.917 0.788 0.909 0.933 0.833 0.923 0.943
X-ray 0.833 0.545 0.545 1.000 0.800 0.885 0.788
4 OCT 0.958 0.667 0.545 0.600 0.667 0.942 0.802
X-ray 0.875 0.576 0.364 0.800 0.767 0.962 0.787
5 OCT 1.000 0.939 0.727 0.867 0.700 0.769 0.782
X-ray 1.000 0.818 0.727 0.800 0.633 0.808 0.813
6 OCT 0.917 0.697 0.909 0.867 0.767 0.846 0.905
X-ray 0.521 0.394 0.455 0.867 0.933 0.942 0.798
7 OCT 1.000 0.788 0.455 0.667 0.667 0.981 0.862
X-ray 1.000 0.697 0.455 0.333 0.733 0.942 0.879
8 OCT 0.833 0.636 0.364 1.000 0.933 0.962 0.845
X-ray 0.792 0.545 0.636 1.000 0.900 0.962 0.836
9 OCT 0.958 0.879 0.818 1.000 0.933 0.904 0.915
X-ray 0.917 0.788 0.727 0.867 0.733 0.808 0.853
10 OCT 0.771 0.636 0.364 0.867 0.900 0.981 0.848
X-ray 0.833 0.424 0.455 1.000 0.867 0.962 0.818
11 OCT 1.000 0.848 0.909 0.733 0.600 0.731 0.837
X-ray 0.917 0.727 0.636 1.000 0.767 0.827 0.844
12 OCT 0.979 0.879 0.909 0.733 0.700 0.865 0.879
X-ray 0.896 0.818 0.545 0.867 0.667 0.885 0.781
13 OCT 0.979 0.758 1.000 1.000 0.933 0.885 0.951
X-ray 0.958 0.424 0.182 1.000 0.833 0.942 0.764
Average (SD) OCT 0.946 a
(0.068)
0.788 c
(0.102)
0.741 e
(0.219)
0.826 g
(0.132)a
0.764 h
(0.120)
0.885 k
(0.109)
0.859 m
(0.057)
X-ray 0.873 b
(0.118)
0.643 d
(0.163)
0.559 f
(0.170)
0.841 g
(0.186)
0.767 h
(0.093)
0.870 k
(0.095)
0.810 n
(0.030)

Notes: Cutoff values: a significant difference was observed in sensitivity and area under receiver operating characteristic (ROC) curve (Az) between optical coherence tomography (OCT) and radiography (p< 0.05), whereas no such difference in specificity was shown. Different superscripts letters indicated significant difference.