Skip to main content
. 2020 Feb 5;27(e1):e87–e92. doi: 10.1136/ejhpharm-2019-002076

Table 2.

Cumulative amount of vancomycin infused over 24 hours at 25°C (n=5 syringes), infused at 0.8 mL/hour for vancomycin syringes at 25 mg/mL and at 2 mL/hour for vancomycin syringes at 40–60 and 80 mg/mL

Vancomycin concentration (mg/mL) Solvent for reconstitution Cumulative quantity (mg) at 24 hours, median (IQR) (% loss±SD) P value
WFI vs saline solution F vs NF
With filter Without filter F NF
25  WFI 452 (2) (6.2±0.8) 444 (5) (7.1±0.6) 0.063 0.905 0.071
Saline solution 447 (2) (7.1±0.5) 448 (4) (7.1±1.6) 0.690
40  WFI 1663 (5) (13.5±0.5) 1662 (4) (13.4±0.1) 0.012* 0.008* 0.802
Saline solution 1645 (6) (14.3±0.3) 1651 (8) (14.0±0.6) 0.087
60  WFI 2563 (2) (11.0±0.3) 2601 (10) (9.7±0.2) 0.012* 0.008* 0.008*
Saline solution 2531 (4) (12.1±0.4) 2550 (1) (11.5±1.1) 0.012*
80  WFI 3314 (4) (13.7±0.1) 3284 (1) (14.4±0.3) NA NA 0.012*
Saline solution NA NA NA

*P<0.05.

F, filtered; NA, not applied; NF, non-filtered; WFI, water for injection.