Skip to main content
. 2020 Mar 17;17:612–621. doi: 10.1016/j.omtm.2020.03.014

Table 6.

Summary of Results from JΔNI5 Vector Production Runs using the Conventional and the Optimal Protocol (n = 3)

Total gc Total PFU gc/PFU
Conventional protocol 6.8 ± 0.35 × 1010 4.7 ± 2.3 × 107 1,827 ± 730
Optimal protocol 1.9 ± 0.17 × 1011 1.8 ± 0.99 × 108 1,408 ± 710