Prediction accuracy for the Box Behnken design optimization process.

Batch Response Prediction Accuracy
Predicted Actual Residual % P.E.
A % RIF released at 0.5 h (R1) 15.39 15.65 0.26 1.66
% RIF released at 2 h (R2) 36.99 38.04 1.05 2.76
% RIF released at 4 h (R3) 48.58 49.18 0.6 1.22
% RIF released at 6 h (R4) 68.71 65.70 3.01 4.58
% RIF released at 8 h (R5) 76.55 78.55 2 2.55
Encapsulation efficiency (%) (R6) 94.71 94.80 0.09 0.095
% Buoyancy (R7) 62.23 58.62 3.61 6.16
Floating lag time (seconds) (R8) 149.63 144 5.63 3.91
% RIF released at 12 h (R9) 92.12 87.89 4.23 4.81
% Yield (R10) 82.19 81.95 0.24 0.29
B % RIF released at 0.5 h (R1) 15.39 15.81 0.42 2.66
% RIF released at 2 h (R2) 36.99 38.58 1.59 4.12
% RIF released at 4 h (R3) 48.58 49.11 0.53 1.08
% RIF released at 6 h (R4) 68.71 64.57 4.14 6.41
% RIF released at 8 h (R5) 76.55 77.08 0.53 0.688
Encapsulation efficiency (%) (R6) 94.71 99.19 4.48 4.52
% Buoyancy (R7) 62.23 56.22 6.01 10.69
Floating lag time (seconds) (R8) 149.63 140 9.63 6.88
% RIF released at 12 h (R9) 92.12 86.44 5.68 6.57
% Yield (R10) 82.19 87.97 5.78 6.57
C % RIF released at 0.5 h (R1) 15.39 16.03 0.64 3.99
% RIF released at 2 h (R2) 36.99 39.32 2.33 5.93
% RIF released at 4 h (R3) 48.58 47.22 1.36 2.88
% RIF released at 6 h (R4) 68.71 66.73 1.98 2.97
% RIF released at 8 h (R5) 76.55 78.44 1.89 2.41
Encapsulation efficiency (%) (R6) 94.71 96.99 2.28 2.35
% Buoyancy (R7) 62.23 55.81 6.42 11.50
Floating lag time (seconds) (R8) 149.63 142 7.63 5.37
% RIF released at 12 h (R9) 92.12 94.71 2.59 2.74
% Yield (R10) 82.19 85.88 3.69 4.20