Skip to main content
. 2020 Mar 27;2020:8067657. doi: 10.1155/2020/8067657

Table 2.

Summary of results of recent studies evaluating the photopic binocular distance CSF in presbyopic patients wearing contact lenses for presbyopia correction. Units are LogCS.

Author (year) Lens type/fitting n (Rx) (age) LogCS (1.5 cpd) Log CS (3 cpd) Log CS (6 cpd) Log CS (12 cpd) Log CS (18 cpd)
Gupta et al. (2009) [99] Monovision
Purevision MF
20 (−1.42 ± 2.87)
(55.0 ± 5.1)
1.75
1.75
1.89
1.93
1.77
1.74
1.33
1.12
0.68
0.65

García-Lázaro et al. (2012) [100] Monovision
Pinhole
22 (0.11 ± 0.12)
(57.3 ± 5.8)
1.49
1.40
1.69
1.64
1.46
1.41
0.94
0.90
0.63
0.60

Llorente-Guillemot et al. (2012) [101] Spectacles
Purevision MF
20 (−1.42 ± 2.87)
(53.2 ± 5.3)
1.51 1.76 1.69 1.28 0.67

Madrid-Costa et al. (2013) [102] Purevision MF
Oasys MF
20 (+0.35 ± 1.78)
(45.1 ± 2.3)
1.63
1.54
1.73
1.73
1.35
1.33
1.09
1.07
0.7
0.67

Bakaraju et al. (2018) [103] Airoptix
Oasys MF
EDOF
43 (−0.65 ± 0.88) (53 ± 5) 1.47
1.44
1.44
1.26
1.21
1.21
1.01
0.92
0.95